NEC (Articles 320, 348, 353, 354, 355, 360, 362)

12345678910111213141516171819202122232425262728
Across
  1. 3. Article 354
  2. 5. Bends of NUCC shall be so made that the conduit will not be damaged and that the internal ________ of the conduit will not be effectively reduced.
  3. 7. Type AC cable shall be permitted to be run or fished in the air voids of masonry block or tile walls where such walls are not exposed or subject to excessive ________ or dampness.
  4. 8. Article 362
  5. 13. This article covers the use, installation, and construction ______________ for reinforced thermosetting resin conduit and associated fittings.
  6. 15. Angle connectors shall not be used for _________ raceway installations. (flexible metal conduit)
  7. 16. HDPE conduit shall not be used in exposed locations, except as permitted by 353.10(5) where _______ in concrete.
  8. 17. FMT shall not be used in hazardous (classified) locations, except as permitted by other ________ of this Code.
  9. 18. There shall not be more than the __________ of four quarter bends (360 degrees total) between pull points, for example, conduit bodies and boxes. (flexible metal conduit)
  10. 20. Armored cable installed in thermal insulation shall have conductors rated at 90°C (194°F). The ________ of cable installed in these applications shall not exceed that of a 60°C (140°F) rated conductor.
  11. 23. For ___________, the conduit shall be trimmed away from the conductors or cables using an approved method that will not damage the conductor or cable insulation or jacket. All conduit ends shall be trimmed inside and out to remove rough edges. (nonmetallic underground conduit with conductors)
  12. 24. FMC of _________________ 12 (trade size 3/8) shall be permitted in lengths not in excess of 1.8 m (6 ft) as part of a listed assembly, or for taps to luminaires as permitted in 410.67(C), or for utilization equipment.
  13. 26. HDPE conduit shall be marked in __________ with 110.21. The marking shall include the manufacturer's name or trademark and shall be at intervals not exceeding 1.5 m (5 ft).
  14. 27. This article covers the use, ____________, and construction specifications for armored cable, Type AC.
  15. 28. The minimum size of RTRC shall be metric designator 16 (trade size ½). The _______ size shall be metric designator 155 (trade size 6).
Down
  1. 1. Article 320
  2. 2. Article 348
  3. 4. NUCC shall be permitted in locations subject to severe corrosive influences as covered in 300.6 and where subject to _________ for which the assembly is specifically approved.
  4. 6. Article 355
  5. 9. This article covers the use, installation, and construction specifications for electrical nonmetallic ______ and associated fittings.
  6. 10. Article 360
  7. 11. Where FMT is bent for installation purposes and is not flexed or bent as required by use after installation, the _____ of bends measured to the inside of the bend shall not be less than specified in Table 360.24(B).
  8. 12. A nonmetallic raceway of circular cross section, with associated couplings, connectors, and fittings for the installation of electrical _________.(highdensity polyethylene conduit)
  9. 14. Article 353
  10. 19. All cut ends of ENT shall be _______ inside and outside to remove rough edges.
  11. 21. In any building exceeding three floors above grade, ENT shall be concealed within walls, floors, and ceilings where the walls, floors, and ceilings provide a _______________ of material that has at least a 15-minute finish rating as identified in listings of fire-rated assemblies.
  12. 22. RTRC shall be installed as a complete system as provided in 300.18 and shall be securely ________ in place and supported in accordance with 355.30(A) and (B). RTRC shall be permitted to be encased in concrete.
  13. 25. Where flexible metal tubing is not flexed after installation, the radii of bends measured to the inside of the bend shall not be less than specified in _____ 360.24(A).