Alaris Pump
Across
- 1. To insert the primed administration set into the pump, hold the upper fitment above the fitment recess and _______ filament into the recess.
- 4. The pump mode that allows a module to be paused indefinitely will be automatically disabled when the power cord is ________________.
- 7. To turn off the entire system at once, including all running channels, use the OPTIONS key labeled ___________________
- 9. To remove an administration set, gently pull the tubing below the _____________________ forward and out.
- 11. To quickly locate a desired drug, use the ______________ menu keys to narrow the search.
- 12. Drug __________ and volume to be infused (VTBI) must be entered before starting the pump.
- 18. Total number of Module Channels that can be added.
- 19. After closing the module door, the administration set roller clamp should be _________.
- 20. After both the upper fitment and the recess fitment are loaded, use a ____________ to firmly push the silastic pumping segment tubing toward the back of the air-in-line (AIL) Detector.
- 21. The pump mode that allows a module to be paused indefinitely can be accessed via what key?
- 22. After loading the administration set into the upper fitment, press the _____________ fitment into the recess below the mechanism.
- 23. When adding a module, rotate it down onto the unit until the bottom latch_______ into place.
- 24. When inserting administration set into the pump, assure the silastic pumping segment is not _________.
Down
- 1. After selecting the channel to program, next select the Guardrail ___________ menu.
- 2. When the pump is first turned on the display will ask if you have a ___________.
- 3. Turning off the only working channel will ___________________ the entire system.
- 5. After priming the tubing, place the _____________ in the closed position.
- 6. Module Channels should be added at a ___________ degree angle to the unit or another module.
- 8. To turn a channel off, press and hold the _____________ key.
- 10. A properly set-up administration set should have ______________ flowing though the drip chamber.
- 13. When a module channel door is opened with an administration set loaded, the safety clamp fitment will automatically _____________ to prevent accidental free-flow of medication.
- 14. What pump mode allows a module to be paused indefinitely without alarming?
- 15. The Alaris PC Point-of-Care Unit is also called the ___________.
- 16. To turn on the Alaris pump, push the _____________ key.
- 17. To program a specific channel, start by pressing the ________________ button.
- 25. While priming the pump tubing be sure to remove air at the injection ports by ___________ them while inverted.