EECE.3110 Assignment 1

123456789101112131415161718192021222324252627282930313233343536373839404142434445464748
Across
  1. 3. Anything over 30V DC or AC (LRSM, 4)
  2. 4. This tool must be lead-free if used in the laboratory. (LRSM,6)
  3. 6. Used to simplify wiring in a schematic; collection of nets. (sim,173)
  4. 9. Should never be used on an electrical fire (LRSM, 4)
  5. 12. By writing this on each page of your Lab Notebook, you can quickly find notes weeks after they were made. (WLNB,78)
  6. 13. Used to store data such as numbers or equations. (mat,13)
  7. 15. Required material for lab to document results. (syl,12)
  8. 19. Group of components that contail resistors, inductors, etc. (sim,63)
  9. 20. Collection of inter-connected circuits. (sim, 160)
  10. 23. Each component has this property when placed on the workspace; numbered in the order they were placed. (sim,169)
  11. 24. Key to writing good notes in the Lab Notebook. (WLNB,63)
  12. 25. Best load setting for each channel on the function generator. (func, 48)
  13. 27. Process of joining CH1 meter readings with CH2 meter readings. (pow,30)
  14. 29. Shorter lab report. (LRSM,37)
  15. 30. Has a rating of 100V-120V and is located in the back of the function generator. (func,32)
  16. 32. Set of key words/phrases used with the remote interface of the power supply. (pow,39)
  17. 35. When this is activated, CH1 and CH2 respond together to any adjustment in voltage. (pow,29)
  18. 37. Enables the oscilloscope to capture a waveform each time a certain condition is met. (oscope,120)
  19. 40. Due date for a project. (syl,8)
  20. 42. The power supply has three of these to deliver DC voltage. (pow,28)
  21. 44. Tool used to acquire waveform signals and display its information. (adk)
  22. 45. Used to check voltage, current, resistance etc in multisim. (sim, 32)
  23. 46. Arrays with multiple rows. (mat,15)
  24. 47. Graded twice a semester and evaluates lab skills. (LRSM,43)
  25. 48. This type of work will result in a 0 for the assignment (syl,3)
Down
  1. 1. Difference between Top and Base values of a waveform. (oscope,180)
  2. 2. "Sine" and "Square" are one of five of these produced by the function generator. (func,27)
  3. 5. Typically the last page in a lab report. (LRSM,34)
  4. 7. Sequence of characters. (mat,25)
  5. 8. User defined settings and waveforms can be saved to this for future use. (func,39)
  6. 10. Similar to the oscilloscope, but has a separate section dedicated to it. (adk)
  7. 11. Setting on a plot that uses a vertical line to track pulse width (adk)
  8. 13. This knob on the oscilloscope controls the volt/div scale. (oscope,59)
  9. 14. The best way to communicate with your TA or Professor Bowden during the week. (syl, 10)
  10. 16. All data in MATLAB is stored in this format. (mat,15)
  11. 17. Manufacturer of the Analog Discovery (syl,13)
  12. 18. Each student must ensure that graded material is accurate on this site. (syl, 8)
  13. 19. Standard cable type that is used to transmit signals from the generator. (func,12)
  14. 21. Manufacturer of the Analog Discovery. (syl,13)
  15. 22. you must do this with each one of your sources in a lab report (LRSM, 8)
  16. 26. Method used to connect an electrical signal from one circuit to another. (adk, section 3)
  17. 28. Channel used on the ADK to plot X/Y of a waveform. (adk,section 3.3)
  18. 31. MATLAB can create 2-D and 3-D versions of this. Often used for graphically representing laboratory data. (mat,29)
  19. 33. This is required after completing a page of notes in the Lab Notebook. (WLNB,30)
  20. 34. Notes should not be taken using this writing instrument (WLNB,24)
  21. 36. Draft lab report done before each lab (LRSM, 13)
  22. 38. Section of the Lab Notebook that outlines whose book it is and what the purpose of the notebook is. (WLNB, 68)
  23. 39. Returns instrument to specified setup. (pow,25)
  24. 41. Configures display to best fit the waveforms on the screen. (oscope,28)
  25. 43. This knob on the oscilloscope controls the time/div setting. (oscope,44)