EECE.3110: Electronics I Lab
Across
- 3. The default setting for placing components is snap to [blank] on Multisim.
- 4. This power supply has a current [blank] that limits the amount of current that can be delivered to the load, ultimately protecting the circuit.
- 5. In MATLAB, the syntax is to include a [blank] to the end of every line.
- 7. If you miss a [blank], expect a deduction on the final grade of the assignment or lab report daily.
- 10. Oscilloscope [blank] are connected to the channels used to measure voltage in a circuit.
- 12. The AFG1022 can produce [blank] different waveforms at the same time.
- 13. An [blank] notebook is used to record laboratory findings and notes from completion of the lab session.
- 14. The software to run the ADK is called [blank].
- 16. Bowden’s office hours are on [blank] from 10:30AM – 11:30AM or by appointment.
- 17. By pressing the [blank] button on the oscilloscope, it will run a single cycle of the wave from a connected circuit.
- 18. The ADK has a [blank] adapter to connect an oscilloscope probe.
- 20. The [blank] function on the oscilloscope can be used to display a specific part of the signal needed.
- 23. To measure current with an ammeter, put the DMM in [blank] with the circuit.
- 25. Multisim is a software for designing [blank] digitally.
- 26. National [blank] owns Multisim and Ultiboard.
- 28. Lab [blank] evaluations are a verbal test to the knowledge preformed in lab and these tests occur twice a semester.
- 31. In MATLAB the file type is a [blank] file.
- 32. The ADK has a built-in [blank], function generator, power supply and digital I/O signals.
- 33. Check [blank] to see your grades and to find all material for the semester.
- 34. [blank] is required to Friday lectures and lab sessions.
- 36. [blank] is the best color of ink to use for proper aging purposes.
- 37. A power supply outputs [blank] current voltage.
- 38. In MATLAB, when using the plot function, at the end include this: ‘r-’. This creates a red [blank].
- 39. Only black or [blank] pen can be used in a laboratory notebook.
Down
- 1. [blank] lab reports are a blessing and don’t require to write a summary/abstract, introduction, the written portion in the measurements section, and the question section.
- 2. Bowden and Phillip’s Office are in [blank].
- 3. The [blank] terminal is to direct the positive charges to go to a safe place and to protect the circuit.
- 4. The university uses [blank] solder because it is safer.
- 6. The most relevant MATLAB help can be found on the [blank] website.
- 8. To learn the basic functions of MATLAB, take the course on the Mathworks website, [blank].
- 9. The [blank] generator is used to produce a periodic wave signal.
- 11. To generate a waveform on a function generator, input the frequency in hertz or period in seconds and the [blank] in volts.
- 12. A function generator can output sine waves, square waves, [blank] waves or also known as ramp waves, etc.
- 15. The [blank] on a wave signal is the amount of cycles per second and can be expressed in the unit Hertz (Hz).
- 16. A [blank] is a component that protects a circuit against too much current.
- 19. There are two to four [blank] on an average oscilloscope which are using to probe circuits.
- 21. [blank] must be completed and submitted to Blackboard prior to the scheduled lab session.
- 22. The bottom of the page requires a [blank] after completion of each page.
- 23. In any blank or empty [blank] cross the area out with an ‘X’.
- 24. Multisim has a [blank] function which allows the circuit to perform the way it should in real time.
- 27. Function generators can create a [blank] waveform, which linearly varies the frequency at a constant amplitude.
- 28. To measure voltage with a voltmeter, put the DMM in [blank] with the desired component.
- 29. This power supply maintains a [blank] voltage and current on channels one and two.
- 30. If you right click on a line and select ‘Color Segment’, you can change the [blank] of the connection line.
- 35. No [blank] or drinking in the lab room; all food and drinks must be placed on the designated table before start of lab.