Hot water revision level 2
Across
- 2. What is the primary function of the open vent on a domestic hot water system?
- 4. picture 6
- 13. A rigid pipework hot water system has a working pressure of 4bar. At what pressure should the pipework be tested for soundness?
- 16. component that the pressure and temperature relief valves discharges into
- 18. all boilers that are installed are required to be what?
- 20. Picture 2 type of localised hot water heater
- 22. what type of heat exchanger does a double feed indirect cylinder contain?
- 23. Picture 1
- 24. what does image 8 measure?
- 29. what type of pump should be used on secondary circulation
- 30. To prevent electrolytic corrosion taking place in a system, where can the magnesium rod be placed?
- 32. a renewebale enery source that produces electricity or hot water
- 35. picture 4 Type of hot water cylinder
- 36. If hard water is allowed to be heated above 65 degrees centigrade, what could be the consequence in the system?
- 37. a renewable source that produces hot water using compressed wood pellets
Down
- 1. the length insulation is required to be on a hot water cylinder
- 3. Building regulation that deals with hot water safety
- 5. name for cheaper priced electricity during the night time
- 6. A 450mm off set on the hot water draw-off point on a cylinder prevents what?
- 7. picture 7
- 8. type of boiler that is mains fed and supply’s hot water instantaneously
- 9. To overcome a dead leg for a hot water draw-off point, what could be installed?
- 10. another method of heating hot water directly in a cylinder
- 11. another term for a water jacket tube heater
- 12. component that protects against category 2 water
- 14. Which hot boosterpump Which hot water component should be fixed using flexible connections
- 15. picture 9
- 17. Under Building Regulations part G, what is a new or replacement immersion heater thermostat required to have?
- 19. Which of the following appliances is most likely to offer the customer low pressure at a hot water outlet?
- 21. tool used to take flow rates
- 24. Building regulation that deals with energy efficiency
- 25. the name given to the layers of hot water in the hot water cylinder
- 26. component that protects against category 3 water
- 27. component that takes the expanded water on a unvented system
- 28. what does secondary return prevent?
- 31. A customer has intermittent flow of hot water from their bath tap – what is the most likely cause of the problem?
- 33. picture 5 Type of hot water cylinder
- 34. Picture 3 Type of hot water cylinder