World water Day FY2017-18
Across
- 5. / I am the acronym of key parameter of cooling water. Lower value indicates better cooling rate and higher value creates scaling.
- 6. / I am the form of water that travel with fastest velocity inside linear assets of sterlite copper.
- 8. / I am the parameter used in water chemistry to quantify the carbonates and bicarbonates of alkali earth metals dissolved in water.
- 9. / I am the name of water treatment process to produce water input to ISA boiler.
- 11. / I cause financial loss to the organizations. To control me, sterlite copper has implemented various technical initiatives in linear asset management.
- 12. / I am measured in mm for a period of time duration. I must be monitored as part of statutory norms before implementation of any huge project.
- 14. / I am the location name of nearest pumping station of TWAD.
- 15. / I am a measure to quantify the change of phases. I am monitored in energy efficiency calculation of all thermal power stations.
- 16. / I am followed by sterlite environment team to save water for gardening.
- 21. / I am restricted to reach admin building of sterlite copper by construction of speed brake.
- 23. / I am French word and expansion of two letter acronym used to measure a key parameter of water quality.
- 24. / I am the most ignored form of water inside Sterlite copper. I can be used for localized heating applications.
- 25. / I am acronym of vessel in Water treatment plant of Utility in Sterlite Copper. I am fore-most water treatment. I remove suspended solids. I am counted 5 in Utility pump house.
- 29. / I am a measure of concentration measured in mole per unit volume
- 32. / I am the most compact of flow measurement devices. I am cheapest and easiest to install. I can easily be altered for measurement of various ranges of flow rate.
- 33. / I am the process of producing solutions
- 35. / I am the location of most distant pump that delivers water to Sterlite copper.
- 36. / I am key part of every boiler to prevent corrosion. I work on the principle of removing impurities by heating.
- 37. / Limiting value of TDS of intake water to Sterlite copper.
- 39. / I am a measure of concentration measured in mole per unit mass.
- 41. / Loss caused by me is inversely proportional to relative humidity of ambient air.
- 43. / I am the acronym max. capacity of water flow rate from TWAD to industries of SIPCOT and government operated power stations of Tuticorin
- 44. / Energy or heat required for phase change at constant temperature.
- 45. / I am a water soluble mixture of different dyes extracted from lichens.
- 46. / I am acronym of vessel called by three words. Before entering SAP and PAP boilers, every drop of water should pass though me. I am counted 3 no’s in Utility of Sterlite copper.
Down
- 1. / If you don't let me leave from system, I will spoil the system. I am related to Cooling water.
- 2. / Field of engineering related to physical and thermodynamic properties of gas-vapor mixtures.
- 3. / I am the term used to measure key solute in aerosol you need every time to live.
- 4. / I am a financial loss. I exist in all open reservoirs & I am presently unquantified within sterlite copper.
- 7. / Source South Ganga
- 10. / I am counted 4 till November'2015 for raw water storage. From Nov'2015 I am counted 3.
- 13. / I am the process used to remove moisture in instrument air of Sterlite copper.
- 17. / Quality of Water parameters contained in me within sterlite copper needs to be monitored for no contamination.
- 18. / I am measured in micro Siemens.
- 19. / I am stored in ISA building. I am circulated through gravity to all user departments of sterlite copper.
- 20. / Alternate source of water during summer.
- 21. / I am acronym of vessel in cooling water treatment. I remove suspended solids in circulating cooling water.
- 22. / I am newly procured to quantify a key element of water loss. I was commissioned in Mar'2018.
- 26. / I am type of water that is used in boilers of SAP and PAP of Sterlite copper
- 27. / I am unit of measurement of suspended solids of raw water to sterlite copper.
- 28. / I am specifically used for quantifying concentration of acids and bases. I am measured by eq per unit volume.
- 30. / I am the acronym of water parameter used for quantification of anions and cations in water.
- 31. / I am a primary measurement element to find flow rate. I am shortly termed as averaging pitot tube.
- 34. / I am the acronym max. capacity of water flow rate to industries in Tuticorin and Thiruchendur
- 38. / Quantity of heat required to convert unit mass of water into vapor state at 760mm Hg at 100degC. (Approximated to nearest integer & measured in kJ per unit mass)
- 40. / Recovery of me is key part of any energy audit of steam distribution circuits.
- 42. / I am used during PV audits in sterlite copper to account water stock.