Across
- 5. Computer that serves as a digital post-processing station or an image review station.
- 7. Radiographic examination that displays sectional anatomic images in axial, sagitall, or coronal planes.
- 9. Similar to general radiographic tube in a construction and operation.
- 12. An individual matrix box, each pixel is assigned a CT number.
- 15. Technique used to view vessels as demonstrated in CT angiography.
- 18. Replaced the high tension cables and allow for continous rotation of the x-ray tube, which when combined with patient movement through the ganry acquired data in a helical or spiral fashion.
- 19. Central opening in the gantry
- 21. Section of the object that is being scanned.
- 22. Computer workstation a setup in workstation arre situated in other location for us by the radiologist or the technologist .
- 23. A ratio that reflects the relationship between table spped and slice thickness.
- 24. Refers to acquistion of a volume of CT data.
- 25. Undesirable feature or density in an image not representative of anatomy
- 26. Electronically linked to the ganrey for controlled movement during the can. pt. anatomy with the aperture is the area being scanned at that time.
Down
- 1. Refers to the range of the CT number that are displayed as shades of gray.
- 2. image of a CT examination that is used to plan the range of the scan; depending on the vendor, it may be called a topogram/scout.
- 3. Allows the technologist to control the parameters of the examination.
- 4. Consists of the x-ry tube, detector array and collimations.
- 6. Method by which images acquired in the axial plane may be reconstructed in the coronal or sagittal plane.
- 8. Series of rows and colums (of pixels) that give form to the digitial image.
- 10. Solid state and composed of photodiodes coupled with scintillation crystal materal such as ocide ceramic crystal, or cadmium tungstate.
- 11. to reduce patient dose and improves image quality.
- 13. Number that represents the attenuation value for each pixel, relative to water.
- 14. Window level-controls image brightness or deternines the CT number that is the center of he window width.
- 16. predetermined for each producure includes factors such as kilovoltage milliamperage, pitch, field of view. slice thickness, table indexing, reconstruction algorithms, and display window.
- 17. Adjustment of the window level and window width (brightness and image contrast) by the user.
- 20. Two types of highly sophisticated software- one for the operating system and one for applications