Electronics Crossword Puzzle

12345678910111213141516171819202122232425262728293031323334353637383940414243444546
Across
  1. 7. (1+ 1-) and (2+ 2-) in the Analog Discovery 2 are used to capture and analyze analog signals. [Oscilloscope]
  2. 9. “ ./ “ is one of the operators used in MATLAB. [Division]
  3. 12. Virtual instrument suite used for Analog Discovery 2. [Waveforms]
  4. 14. These types of keys are grey. Pressing one of them causes the instrument to perform a specific operation. Config key is an example. [Operation]
  5. 17. The property of a capacitor to store an electrical charge. [Capacitance]
  6. 20. When this feature is enabled, the displayed reading is the difference between the measured input signal and the stored null value. [Null]
  7. 21. This button is used to select the shape of waveform among sine, square, ramp, or arb. [Shape]
  8. 22. This simulation toolbar button starts/resumes the simulation of the active circuit. [Run]
  9. 23. This section of the lab report is a mini version of the lab report. It contains an overview of the lab and the main conclusion(s) drawn from the lab. [Summary]
  10. 25. This menu button is used to perform an automatic setup of oscilloscope settings. [Autoset]
  11. 29. This button can be used to set the output load value to either 50 Ohms or High Z mode. [Output Setup]
  12. 30. All assignments are to be submitted here using Blackboard. [Assignment Module]
  13. 31. Required as a proof of author’s work and can also be used to provide a proof of witness. [Signature]
  14. 34. This is a function that provides value of 3.14159265… [pi]
  15. 36. This display button is used to activate the system utility functions, such as selecting a language or setting the date/time. [Utility]
  16. 37. This graphs properties button specifies a label for the trace. [Label]
  17. 39. The process of connecting the output signal back to the input of the same amplifier. [Feedback]
  18. 40. This sign indicates an injury hazard not immediately accessible as you read the marking. [Warning]
  19. 42. It is highly recommended that you back-up all lab data onto this device. [Memory Stick]
  20. 43. This mathematical function calculates the ratio of measured reading to a specified target value in the form of percentage. [Percent]
  21. 44. This trigger option selects the internal trigger source. [Internal]
  22. 45. This sign in waveforms shows that the device is armed and is waiting for a trigger event to occur. [Armed]
  23. 46. Indicating the page numbers after the end of each page. [Numbering]
Down
  1. 1. Device used to apply specified analog signals to circuits. [Wavegen]
  2. 2. This analog acquisition mode retains the first sampled point from each acquisition interval. [Sample]
  3. 3. When using devices such as the Analog Discovery and the Oscilloscope, screenshot/capture submissions must include this number along with the date and time it was taken. [Serial Number]
  4. 4. Abbreviation for “Metal oxide field effect transistor”. [MOSFET]
  5. 5. A type of circuit that is used to compare two inputs. [Comparator]
  6. 6. The functions “ A ^ (1/2) and “ A. ^ (1/2)” are used to solve these types of math functions. [Exponentials]
  7. 8. This is a hands-on laboratory evaluation of your laboratory knowledge and skills. [Lab Proficiency]
  8. 10. Enables/Disables the averaging digital filter. [Filter]
  9. 11. This menu button is used to perform automated measurements on waveforms and to access the digital voltmeter and waveform histogram functions. [Measure]
  10. 13. This math software package is to be used to perform all the calculations and it can also be used to draw a graph. [MatLab]
  11. 15. This component toolbar button selects the source components group in the browser. [Place Source]
  12. 16. Number of stroke(s) needed to cross out the incorrect data in the notebook. [Single]
  13. 17. Multidimensional arrays in MATLAB whose elements are copies of other arrays. [Call Arrays]
  14. 18. This analog acquisition mode calculated the average value for each record point over a user specified number of acquisitions. [Average]
  15. 19. This instrument toolbar button places the multimeter on the workspace. [Multimeter]
  16. 24. This section of the lab report is considered as the heart of note writing. It includes data that is gathered from taking all the measurements. [Observation]
  17. 25. This is one of the two acceptable formats for referencing in your lab report. [APA]
  18. 26. This indicator indicates that the external triggering is enabled. [Trig]
  19. 27. “ .^ “ is one of the operators used in MATLAB. [Power]
  20. 28. This button in Output options tab prints the circuit and faces of the instruments used in the circuit on a separate sheet. [Instruments]
  21. 32. A type of circuit that is used to increase the voltage, current, or power of a signal. [Amplifier]
  22. 33. Call them in case of an emergency. From Lab Phone use x44911 and from Cell Phone use 9789344911. [University Police]
  23. 34. (V+ V-) in the Analog Discovery 2 are used to supply power to a circuit. [Power Supply]
  24. 35. Last name of the author of “Writing the Laboratory Notebook”. [Kanare]
  25. 38. Practice of copying someone’s work or ideas. [Plagiarism]
  26. 41. These types of keys are white. Pressing one of them causes the instrument to perform a specific function. DCV key is an example. [Function]
  27. 42. These coverings are required for all students regardless of vaccination status in all indoor spaces. [Masks]