Across
- 2. equipment intended to be carried by a person which can be moved when energized
- 3. inspection which identifies, without the use of access equipment or tools, those defects, such as missing bolts, which will be apparent to the eye
- 5. Acronym for Dangerous Substances and Explosive Atmosphere Regulations, this regulation is the resulting UK
- 7. means of repair involving, for example, the removal or addition of material to reclaim component parts which have sustained damage, in order to restore such parts to a serviceable condition in accordance with the relevant standard
- 8. change to the design of the equipment which affects material, fit, form or function
- 10. maker of the equipment (who may also be the supplier, the importer or the agent) in whose name usually the certificate, where appropriate, of the equipment was registered
- 12. inspection which encompasses those aspects covered by a close inspection and, in addition, identifies those defects, such as loose terminations, which will only be apparent by opening the enclosure, and/or using, where necessary, tools and test equipment
- 15. Acronym for Control of Major Accident Hazard
- 18. an indivisible item Note: The assembly of such items may form equipment.
- 19. equipment intended to be supported by a person’s body during normal use
- 22. document that assures the conformity of a product, process, system, person, or organization with specified requirements
- 23. action comprising careful scrutiny of an item carried out either without dismantling, or with the addition of partial dismantling as required, supplemented by means such as measurement, in order to arrive at a reliable conclusion as to the condition of an item
- 24. an area in which an explosive gas atmosphere is not likely to occur in normal operation but, if it does occur, it will exist for a short period only
- 25. action to restore to a fully serviceable condition equipment which has been in use or in storage for a period of time but which is not faulty
- 27. action to restore faulty equipment to its fully serviceable condition complying with the relevant standard
Down
- 1. Lowest liquid temperature at which, under certain standardized conditions, a liquid gives off vapours in a quantity such as t
- 4. inspection of all electrical equipment, systems and installations before they are brought into service
- 6. inspection which encompasses those aspects covered by a visual inspection and, in addition, identifies those defects, such as loose bolts, which will be apparent only by the use of access equipment
- 9. combination of any actions carried out to retain an item in, or restore it to, conditions in which it is able to meet the requirements of the relevant specification and perform its required functions
- 11. equipment not intended to be carried by a person nor intended for fixed installation which can be moved when energized
- 13. an area in which an explosive gas atmosphere is present continuously or for long periods or frequently
- 14. equipment fastened to a support, or otherwise secured in a specific location when energized
- 16. change to a product that results in an alternative construction that is described in the certificate documentation
- 17. an area in which an explosive gas atmosphere is likely to occur periodically or occasionally in normal operation
- 20. inspection of all electrical equipment, systems and installations carried out on a routine basis
- 21. inspection of a representative proportion of the electrical equipment, systems and installations
- 26. Acronym for 2 EU directives issued to the national governments to create laws on the subject of "Atmosphères Explosibles"