Across
- 3. During a bronchoscopy Dr. Danielson wants use the 2.4 mm flexible cryo probe. The ___________ scope would be used during this case.
- 5. You are taking biopsies with Dr. Carlin using the neonatal gastroscope. Which biopsy forcep would you use?
- 7. Dr. Mallen is going to place valves during a bronchoscopy. The deployment catheter has a minimum working channel diameter of 2.6 mm. Which bronchoscope would you use?
- 10. Dr. Hancock is performing an EUS using the linear EUS scope and wants to obtain fine needle aspirate samples for the pathologist to read. Which needle would you use?
- 12. During an ERCP Dr. Rice wants to perform biliary dilation. This dilation balloon with a minimum working channel of 4.2 mm should be used.
- 14. This roth net has a minimum working channel diameter of 1.8 mm and can be used with the neonatal gastroscope.
- 15. Dr. Salib would like to collect a brushing specimen during a bronchoscopy with the XP190. Which cytology brush should be used (Name is on the package of the brush)?
- 16. This protected cytology brush can be used to test for candida in the esophagus and has a minimum working channel diameter of 2.2mm.
- 18. Dr. Mallen is placing valves during a bronchoscopy using the therapeutic scope and wants to test for an air leak. The ______ balloon should be used.
- 19. This endoscopic tool is used to “stretch” the esophagus and has a minimum working channel diameter of ≥2.8mm.
Down
- 1. This roth net has a minimum working channel diameter of 3.2 mm and can only be used with the therapeutic gastroscope.
- 2. During a food impaction case using a 190 gastroscope with Dr. Iyer she asks for retrieval basket. Which retrieval basket is NOT compatible with the 190 gastroscope?
- 4. This endoscopic tool uses bipolar cautery to treat a bleeding source and has a minimum working channel of 2.4mm.
- 6. This biopsy forcep can be used through the cholangioscope and has a minimum working channel diameter of 1.2mm.
- 8. Dr. Myneni wants to get a brushing sample from the common bile duct during an ERCP. Which cytology brush is appropriate to obtain this sample using the ERCP scope?
- 9. This basket has a minimum working channel diameter of 1.1mm and can be used to remove a foreign body in the airway.
- 11. Dr. Sondhi would like to place a 7 Fr double pigtail stent during an EGD. He would need to use the ____________ scope.
- 13. During a routine bronchoscopy using the P190 bronchoscope, Dr. Trump wants to obtain a brushing specimen. Which cytology brush would typically be used with this scope?
- 17. This stent has a minimum working channel of 3.7 mm and is typically deployed using cautery and the linear EUS scope.
- 20. This gastroscope can be used for pediatric patients or patients that have severe esophageal strictures. The working channel of this scope is 2.2 mm.
