Across
- 4. Restricting the x-ray beam to reduce scatter and dose
- 7. Converts x-rays to visible light to brighten fluoroscopic images
- 8. Radiation safety principle to keep doses “as low as reasonably achievable”
- 9. Source-to-image distance; affects magnification and image sharpness
- 12. Angled projection used to view anatomy not seen on AP or lateral
- 15. Contrast study of a joint under fluoroscopic guidance
- 17. Image-guided system tracking surgical instruments in real time
- 18. Area covered by x-ray beam at patient surface
- 19. Contrast study of bile ducts during surgery
- 21. Subtracted overlay image guiding catheter placement in vessels
- 22. Short bony bridge targeted for spinal screw placement
- 27. Worn by staff to protect from scattered radiation exposure
- 29. Real-time x-ray imaging used to guide surgical procedures
- 30. Plastic or disposable sheath keeping imaging equipment sterile
- 32. Central point around which the C-arm rotates
- 33. OR table level affecting C-arm geometry and dose
- 35. Scatter radiation traveling back toward x-ray tube
- 37. Digital detector replacing image intensifiers in modern systems
- 38. Joint replacement surgery checked with fluoroscopy
- 39. Stabilizing a fracture using plates, rods, or screws
- 40. Inside the bone canal; describes nails or rods used in surgery
- 42. Collar shield protecting the thyroid gland during imaging
- 43. Sterile barrier covering the flat-panel detector
Down
- 1. Realignment of bone fragments before fixation
- 2. Captures x-rays and converts them into digital signals
- 3. Device that activates fluoroscopy while keeping hands sterile
- 5. Object-to-image distance; affects magnification and spatial resolution
- 6. Covering C-arm or detector to maintain sterile field
- 9. Secondary radiation produced when x-rays deflect off patient
- 10. Image enlargement caused by increased object-image distance
- 11. Flexible wire used to guide placement of catheters or screws
- 13. Hollow design allowing passage over a guidewire
- 14. Device that absorbs scatter radiation to improve image contrast
- 15. Practice of preventing contamination during sterile procedures
- 16. Plane dividing body into left and right halves
- 19. Adjustable shutters that shape and limit the beam
- 20. Worn device that records radiation exposure to personnel
- 23. Procedure injecting cement into vertebra to restore height
- 24. Material that allows x-rays to pass through easily
- 25. Beam travels from front to back of patient
- 26. Surgical specialty that frequently uses intraoperative imaging
- 28. Fluoroscopy mode that reduces dose using intermittent x-ray pulses
- 31. Surgical removal of vertebral lamina, often under C-arm guidance
- 34. Function that freezes final fluoroscopic frame to limit exposure
- 36. Mobile x-ray unit used during surgery
- 41. Beam travels side-to-side; used for spine and limb imaging